Home Products Spinsolve family Benchtop NMR Spinsolve 60 MHz
Overview
Whether in the classroom, research laboratory or production line, Spinsolve 60 combines unmatched affordability with exceptional performance to save you time, space and money.
Download resources
- Brochure Spinsolve 60 MHz
- Brochure Spinsolve Ultra
- Brochure Spinsolve 60 Multi X
- Application Note RM - Diimine
- Case Study Spinsolve - Ethylcrotonate
- Case Study Spinsolve - Quinine
- Case Study Spinsolve - Gibberellic Acid
- Case Study Spinsolve - Cholesterol
- Case Study Spinsolve - Brucine
- Case Study Spinsolve - Artemisinin
- Case Study Spinsolve - Fatty Acids
- Case Study Spinsolve - Pesticides
Features of Spinsolve 60 MHz
- 1H frequency: 60 MHz
- 1H and 19F on all systems + X nuclei for dual channel systems
- Resolution:
- Spinsolve 60 : <0.5 Hz (50%) / <20 Hz (0.55%)
- Spinsolve 60 Plus: <0.35 Hz (50%) / <10 Hz (0.55%)
- Spinsolve 60 Ultra: <0.2 Hz (50 %) / <7 Hz (0.55%) / <14 Hz (0.11%)
- Exceptional Sensitivity: 200:1 (Single channel) / 130:1 (Double channel) for 1% Ethyl Benzene
- 3D PFG gradients optimized for gradient-enhanced methods
- Optional PFG gradients for diffusion spectroscopy (>0.5 T/m)
- No cryogens
- Unparalleled stability
- External Hardware Lock with no need for deuterated solvents
- Suitable for on-line reaction monitoring
- Easy to operate
- Compatible with automatic sample changer
Online NMR
The high sensitivity and resolution combined with low weight, stability and robustness makes the Spinsolve 60 the ideal instrument for flexible online NMR-applications.
It can be installed directly in the fume hood of a chemistry lab to monitor the progress of chemical reactions on-line. Reactants can be pumped in continuous mode from the reactor to the magnet and back using just standard PTFE tubing or using PTFE tubing plus a glass flow cell.
Resources
Specifications
- Frequency: 60 MHz
- Nuclei: All models measure 1H and 19F and have the option to include one or more nuclei like 7Li, 11B, 13C, 15N, 23Na, 29Si, 31P (ask for others)
- Resolution :
- Spinsolve 60: 50% < 0.5 Hz / 0.55% < 20 Hz
- Spinsolve 60 Plus: 50% <0.35 Hz / 0.55% <10 Hz
- Spinsolve 60 ULTRA: 50% < 0.2 Hz / 0.55% < 7 Hz / 0.11% < 14Hz
- Spinning: Not required. Compressed air: Not required
- Sensitivity (*): > 200:1 for 1H/19F, and > 130:1 for multinuclear option
- Sample: Standard 5 mm OD NMR sample tubes, minimum length 7″
- External Hardware Lock with no need for deuterated solvents
- Stray Field: 2G line completely inside spectrometer
- Weight: 60 kg
- Dimensions: 58 x 43 x 40 cm (23” x 17” x 16”)
- Operating Temperature Range: 18° C to 28° C (65° F to 82° F)
- Voltage Requirement: 100-240 VAC, 50/60 Hz
(*) Sensitivity measured in a single scan on a 1% ethylbenzene sample dissolved in deuterated chloroform. The signal used for the calculation is the one of the methylene group and the noise is calculated for a signal free region between the aromatic and the methylene signals.
Applications
- Research Laboratories
- Industrial QA/QC Laboratories
- Undergraduate Education